| Product Specification |
| Sensor type |
Continuous auto sampling |
| Function |
Local LCD display type
Intelligent set-up function
Transmitter type |
| Service |
Indoor or outdoor locations
Including hazardous areas |
| Measuring range 1 |
O-2000 ppm
Semiconductor cell |
| Measuring range 2 |
0-100% LEL
Catalytic cell |
| Measuring range 3 |
0-100% Volume
Thermal condductivity cell |
| Sensor life |
3 to 5 years typical |
| Accuracy |
± 3% of full scale |
| Response time |
T90 < 15 sec. with 100% LEL methane applied |
| Zero drift |
Less than 3% of full scale per year |
| Electrical Classfication |
Explosion-proof, Ex d IIC T5 |
| Warranty |
One year |
| Approval |
Korea Ocupational safety association |
| Environmental specification |
| Operating Temperature range |
Electronics -40°C to 70°C
Standard sensor -50°C to 80°C
High Temp sensor -50°C to 250°C |
| Storage Temperature range |
-40°C to 70°C |
| Operating Humidity range |
5 to 100% RH |
| Operating Pressure range |
ATM. ± 10% |
| Mechanical specification |
| Wwight |
2.5kg |
| Material(housing) |
Cast aluminum |
| Material(sensor) |
SUS 304 |
| Mounting type |
2" Pupe Mount/Surface Mount |
| Electrical specification |
| Input power |
24V DC nominal
18 to31V DC /230mA max |
| Output signal |
4-20mA(600 chms max load)
Malfunction 2mA
Setup mode 2mA
Cailbration 0mA |
| Alarm signal |
2 x SPDT |
| Cable requirements |
3-wire shield cable. Max distance 2500M |
| Digital communication |
RS-485 MODBUS Stop Bits : 1 |
| Baud Rate |
9600 |
| Parity |
Even |
| Date Bits |
8 |